Page 36 - Journal of Structural Heart Disease Volume 3, Issue 5
P. 36
Case Report
162
the wire, pacing can be performed only after deliver- ing the TTVI system over the wire.
In conclusion, rapid pacing during TTVI using the guidewire as a unipolar electrode is feasible, safe, and easy to perform. It may shorten the duration of and save unnecessary steps during the procedure.
Con ict of Interest
The authors have no con ict of interest relevant to this publication.
Comment on this Article or Ask a Question
References
1. Antunes MJ, Barlow JB. Manage- ment of tricuspid valve regurgitation. Heart. 2007;93:271–276. DOI: 10.1136/ hrt.2006.095281
2. Nath J, Foster E, Heidenreich PA. Impact of tricuspid regurgitation on long-term sur- vival. J Am Coll Cardiol. 2004;43:405–409. DOI: 10.1016/j.jacc.2003.09.036
3. Jeganathan R, Armstrong S, Al-Alao B, Da- vid T. The risk and outcomes of reoperative tricuspid valve surgery. Ann Thorac Surg. 2013;95:119–124. DOI: 10.1016/j.athorac- sur.2012.08.058
4. McCarthy PM, Bhudia SK, Rajeswaran J, Hoercher KJ, Lytle BW, Cosgrove DM, et al. Tricuspid valve repair: durability and risk factors for failure. J Thorac Cardiovasc Surg. 2004;127:674–685. DOI: 10.1016/j. jtcvs.2003.11.019
5. 5. Chang B-C, Lim S-H, Yi G, Hong YS, Lee S, Yoo K-J, et al. Long-term clinical results of tricuspid valve replacement. Ann Thorac Surg. 2006;81:1317–1324. DOI: 10.1016/j. athoracsur.2005.11.005
6. Guenther T, Noebauer C, Mazzitelli D, Busch R, Tassani-Prell P, Lange R. Tricuspid
valve surgery: a thirty-year assessment of early and late outcome. Eur J Cardiothorac Surg. 2008;34:402–409. DOI: 10.1016/j. ejcts.2008.05.006
7. Marquis-Gravel G, Bouchard D, Perrault LP, Pagé P, Jeanmart H, Demers P, et al. Retrospective cohort analysis of 926 tri- cuspid valve surgeries: clinical and hemo- dynamic outcomes with propensity score analysis. Am Heart J. 2012;163:851–858.e1. DOI: 10.1016/j.ahj.2012.02.010
8. Aboulhosn J, Cabalka AK, Levi DS, Himbert D, Testa L, Latib A, et al. Transcatheter valve-in-ring implantation for the treat- ment of residual or recurrent tricuspid valve dysfunction after prior surgical re- pair. JACC Cardiovasc Interv. 2017;10:53– 63. DOI: 10.1016/j.jcin.2016.10.036
9. McElhinney DB, Cabalka AK, Aboulhosn JA, Eicken A, Boudjemline Y, Schubert S, et al. Transcatheter tricuspid valve-in-valve implantation for the treatment of dysfunc- tional surgical bioprosthetic valves: an international, multicenter registry study. Circulation. 2016;133:1582–1593. DOI: 10.1161/CIRCULATIONAHA.115.019353
10. Faurie B, Abdellaoui M, Wautot F, Staat P, Champagnac D, Wintzer-Wehekind J, et al. Rapid pacing using the left ventricular guidewire: reviving an old technique to simplify BAV and TAVI procedures. Cath- eter Cardiovasc Interv. 2016;88:988–993. DOI: 10.1002/ccd.26666
11. Hilling-Smith R, Cockburn J, Dooley M, Parker J, Newton A, Hill A, et al. Rapid pacing using the 0.035-in. retrograde left ventricular support wire in 208 cases of transcatheter aortic valve implantation and balloon aortic valvuloplasty. Cathe- ter Cardiovasc Interv. 2017;89:783–786. DOI: 10.1002/ccd.26720
Journal of Structural Heart Disease, October 2017
Volume 3, Issue 5:157-162
Cite this article as: Eitan A, Roguin A, Kerner A. Rapid Pacing Using the Guidewire During Transcatheter Tricuspid Valve-in-Valve Implantation. Structural Heart Disease 2017;3(5):157-162. DOI: https://doi. org/10.12945/j.jshd.2017.024.17