Page 30 - Journal of Structural Heart Disease Volume 5, Issue 3
P. 30

69
Original Scientific Article
  ment. This would further improve the predictive val- ue of cardiac MRI for PPVR candidacy.
Conclusion
cSFFP MRI measurements show moderate correla- tion and agreement with BWD of the RVOT. While the mean difference is low, the lines of agreement are quite wide. This suggests MRI is only moderately ef- fective in determining RVOT diameter candidacy in PPVR. Further study using larger patient samples is warranted to determine if MRI is an effective method
to prospectively assess RVOT candidacy for PPVR and to determine the most effective method to screen for PPVR candidacy based on RVOT diameter.
Conflict of Interest
The authors have no conflict of interest relevant to this publication.
Comment on this Article or Ask a Question
 References
1. Schievano S, Coats L, Migliavacca F, Nor- man W, Frigiola A, Deanfield J, et al. Vari- ations in Right Ventricular Outflow Tract Morphology Following Repair of Congen- ital Heart Disease: Implications for Percu- taneous Pulmonary Valve Implantation. J Cardiovasc Magn Reson. 2007;9:687-695. PMID: 17578725
2. Phillips AB, Nevin P, Shah A, Olshove V, Garg R, Zahn EM. Development of a Novel Hybrid Strategy for Transcatheter Pulmo- nary Valve Placement in Patients Following Transannular Patch Repair of Tetralogy of Fallot. Catheterization and Cardiovascular Interventions. J Cardiovasc Magn Reson. 2016;87:403-410. DOI: 10.1002/ccd.26315
3. Lurz P, Bonhoeffer P, Taylor AM. Percu- taneous Pulmonary Valve Implantation: An Update. Expert Rev Cardiovasc Ther. 2009;7:823-833. DOI: 10.1586/erc.09.57
4. Zahn EM, Chang JC, Armer D, Garg R. First human implant of the Alterra Adaptive Prestent(TM) : A new self-expanding de- vice designed to remodel the right ven- tricular outflow tract. Catheter Cardiovasc Interv. 2018;91:1125-1129. DOI: 10.1002/ ccd.27581
5. Malone L, Fonseca B, Fagan T, et al. Prepro- cedural Risk Assessment Prior to PPVI with CMR and Cardiac CT. Pediatric cardiology. 2017;38:746-753. DOI: 10.1007/s00246- 017-1574-0
6. Selly JB, Iriart X, Roubertie F, Mauriat P,
Marek J, Guilhon E, et al. Multivariable As- sessment of the Right Ventricle by Echo- cardiography in Patients With Repaired Tetralogy of Fallot Undergoing Pulmo- nary Valve Replacement: A Comparative Study With Magnetic Resonance Imaging. Arch Cardiovasc Dis. 2015;108:5-15. DOI: 10.1016/j.acvd.2014.07.054
7. Stefanescu Schmidt AC, Armstrong A, Ken- nedy KF, Nykanen D, Aboulhosn J, Bhatt AB. Prediction of Adverse Events After Catheter-Based Procedures in Adoles- cents and Adults With Congenital Heart Disease in the IMPACT Registry. Eur Heart J. 2017;38:2070-2077. DOI: 10.1093/eu- rheartj/ehx200
8. Biglino G, Verschueren P, Zegels R, Tay- lor AM, Schievano S. Rapid Prototyping Compliant Arterial Phantoms for In-Vitro Studies and Device Testing. Journal of Cardiovascular Magnetic Resonance. J Cardiovasc Magn Reson. 2013;15:2. DOI: 10.1186/1532-429x-15-2
9. Gillespie MJ, Benson LN, Bergersen L, Ba- cha EA, Cheatham SL, Crean AM, et al. Pa- tient Selection Process for the Harmony Transcatheter Pulmonary Valve Early Feasi- bility Study. Am J Cardiol. 2017;120:1387- 1392. DOI: 10.1016/j.amjcard.2017.07.034
10. Bergersen L, Benson LN, Gillespie MJ, Cheatham SL, Crean AM, Hor KN, et al. Harmony Feasibility Trial: Acute and Short- Term Outcomes With a Self-Expanding
Transcatheter Pulmonary Valve. JACC Car- diovascular interventions 2017;10:1763- 73. DOI: 10.1016/j.jcin.2017.05.034
11. Garay F, Pan X, Zhang YJ, Wang C, Spring- muller D. Early Experience With the Venus Pvalve for Percutaneous Pulmonary Valve Implantation in Native Outflow Tract. Neth Heart J. 2017;25:76-81. DOI: 10.1007/ s12471-016-0932-5
12. Qureshi AM, Bansal N, McElhinney DB, Boudjemline Y, Forbes TJ, Maschietto N, et al. Branch Pulmonary Artery Valve Im- plantation Reduces Pulmonary Regurgita- tion and Improves Right Ventricular Size/ Function in Patients With Large Right Ven- tricular Outflow Tracts. JACC Cardiovasc Interv. 2018;11:541-550. DOI: 10.1016/j. jcin.2018.01.278
   Kurtz J. D. et al.
MRI vs Balloon Waist for Pulmonary Valve
Cite this article as: Kurtz JD, Hlavacek AM, Baker GH. Correlation and Agree- ment of Steady-State Free Processed Imaging Cardiac Magnetic Resonance Imaging and Balloon Waist Diameter of the Right Ventricular Outflow Tract for Percutaneous Pulmonary Valve Replacement. Structural Heart Dis- ease. 2019;5(3):62-69. DOI: https://doi. org/10.12945/j.jshd.2019.028.18








































































   28   29   30   31   32