Page 26 - Journal of Structural Heart Disease Volume 2, Issue 1
P. 26
Original Research Report
20
Video 10. A oppy tip Amplatz Supersti TM guide wire (Boston Scienti c, Marlborough, Massachusetts, USA) being placed in the LSPV. View supplementary video at http://dx.doi. org/10.12945/j.jshd.2016.007.14.vid.10.
Video 12. Corresponding TEE loop depicting the delivery sheath positioned in the LSPV. View supplementary video at http://dx.doi.org/10.12945/j.jshd.2016.007.14.vid.12.
Video 13. Delivery sheath is being advanced over the dilator into the mouth of LSPV. View supplementary video at http://dx. doi.org/10.12945/j.jshd.2016.007.14.vid.13.
Slide # 34:
The ASO being slenderized within the loader fol- lowed by thorough ushing to get rid of the air within the system (Video 8).
Video 11. An Amplatzer TorqVueTM 45° delivery sheath (St. Jude, Plymouth, MN, USA) being passed over the Supersti wire into the mouth of the LSPV. View supplementary video at http:// dx.doi.org/10.12945/j.jshd.2016.007.14.vid.11.
Journal of Structural Heart Disease, February 2016
Volume 2, Issue 1:15-32